In short. A thin frost on the outdoor unit in winter is normal. The air conditioner melts it itself: for a few minutes it stops blowing into the room, steam comes off the outdoor unit and water drips. This is defrosting, and you do not need to do anything. It is a fault when ice builds up at the bottom and stays, the fan hits ice, or only part of the unit is iced. Then switch the unit off and book diagnostics. Do not knock the ice off and do not pour boiling water on it.

Diagram: 1 — thin frost on the outdoor unit, normal; 2 — defrosting: steam and water drops, usually up to 10 minutes, normal; 3 — ice builds up at the bottom and covers the fan, call a technician
Diagram: 1 — thin frost on the outdoor unit, normal; 2 — defrosting: steam and water drops, usually up to 10 minutes, normal; 3 — ice builds up at the bottom and covers the fan, call a technician

Why the outdoor unit freezes

An air conditioner does not heat with electricity directly; it moves heat from outdoors into the house. To take heat even from cold air, the outdoor unit has to be colder than the air around it. So moisture from the air settles on its fins and freezes, just like frost on a window.

The most frost appears not in hard frost but in damp weather around zero: fog, sleet, drizzle. There is a lot of water in the air and it freezes quickly. That is an ordinary Chișinău winter, so you will see defrosting often. In dry frost there is less water in the air and frost grows more slowly.

Frost stops the unit taking heat from the air, so the air conditioner watches for it and melts it from time to time.

What defrosting is

Defrosting means that for a few minutes the unit sends heat not into the room but into the outdoor unit, to melt the frost. What you notice:

  • the indoor unit stops blowing and may close its louvres, so it does not blow cold air at you;
  • the outdoor fan stops;
  • steam comes off the outdoor unit and water drips or runs from the bottom;
  • sometimes there is a click and a hiss: the unit is reversing the refrigerant flow;
  • usually after a few minutes, up to 10, heating continues by itself.

This is not a fault but normal operation. The damper the weather, the more often it defrosts. Why the unit does not blow warm air straight after switching on is covered separately in Why your air conditioner does not blow warm air straight away in winter.

Normal or a fault: how to tell

What you seeNormal?What to do
A thin white frost on the grille and fins of the outdoor unitYesNothing: the unit melts it itself
The indoor unit stops blowing for 5–10 minutes, steam comes off the outdoor unit, water dripsYes, this is defrostingWait, heating comes back by itself
Ice on the ground or balcony under the unitYes, if the unit itself is clear after defrostingGrit the path, check where the water drains
Ice builds up at the bottom of the unit and does not clear after defrostingNoSwitch off and call a technician
The fan hits ice, knocks or does not turnNoSwitch the unit off at once
Only part of the unit or one of the pipes is icedNoDiagnostics: this happens with a refrigerant leak
The unit is covered in frost, no defrost happens, the room keeps getting colderNoDiagnostics

The main rule: after defrosting the unit should be clear. If ice stays and there is more of it each time, something is stopping the water draining, and it will not go away by itself.

Why ice builds up and does not melt

  • The water cannot drain. During defrosting the ice melts and the water runs out through holes in the unit’s base tray. If they are blocked with leaves, fluff or dirt, the water stays in the tray and freezes. Each defrost adds more ice until it reaches the fan.
  • No base tray heater. Some models designed for frost have a heated base tray so the water in it does not freeze. Whether yours has one, the technician checks during winter preparation.
  • The unit sits too low. At a house, a unit placed on the ground or just above it gets buried in snow, and defrost water freezes right underneath. The unit should sit above snow level, on brackets or a stand.
  • Water drips from above. Water and icicles from the roof or a balcony above fall on the unit and freeze. A canopy over the unit helps, with a gap so it does not block the air.
  • A dirty coil. Dust and fluff on the fins block the airflow, so the unit ices up faster and defrosting copes worse.
  • Low refrigerant. The sign is that not the whole unit ices up but only part of it or one pipe, and the unit heats weakly. Refrigerant is not used up by itself, so there is a leak. It has to be found and fixed before recharging.
  • A faulty sensor or valve. The unit does not know it is time to defrost, or cannot switch over. It grows ice and the room keeps getting colder.

The last two causes can only be seen with instruments, so start with diagnostics for 350 lei: the technician measures pressure, current and temperatures, checks the drainage and wiring and gives you the repair price in writing.

What you can do yourself

  • Clear snow around and above the unit by hand or with a brush, without touching the fins. Switch the air conditioner off first.
  • Check there are no icicles above and that water from the roof is not dripping onto the unit.
  • Grit the path or balcony under the unit: defrost water is normal, but ice is dangerous for passers-by.
  • Check the mode and temperature on the remote and the filters in the indoor unit: clogged filters also weaken heating.

What not to do

  • Knock the ice off with a hammer, knife or screwdriver. The coil fins are thin, and so are the copper pipes. A punctured pipe means a refrigerant leak.
  • Pour boiling water on it. The ice on top melts, but the water runs down and freezes again in the tray, blocking it even more.
  • Switch it on and off again and again if the fan is hitting ice: you can break the blades or the motor.
  • Cover a running unit with plastic or a cover: it needs air. A cover is only for when you do not use the air conditioner in winter.

How to keep ice from building up

Before the heating season the unit is worth cleaning and checking. Winter preparation costs 1 200 lei: cleaning both units plus a check of heating, defrosting, drainage and the base tray heater. Afterwards the unit is cleaner, defrost water drains away and ice does not build up.

If you are still choosing an air conditioner for heating, check in the specifications down to what outdoor temperature the model heats. For example, the ZEUS M-Pro heats down to −35 °C and the MDV Infini Nordic down to −30 °C. All such models are in Air conditioners with heating. And for installation at a house, the outdoor unit should sit above snow level and not under the roof runoff; the technician decides this at the free survey.

If the unit does not heat for other reasons, such as leaking, showing an error or blowing cool air, see Air conditioner not heating, leaking or showing an error.

How long and how often a unit defrosts depends on the model and the weather; the figures in this article are a guide. Whether a model has a base tray heater is in its manual, or ask the technician. Service prices as of 17 November 2026.