In short. A 100 m² house usually gets four air conditioners: one in the living room with kitchen and one in each bedroom. The easiest way to see how much heat you need is the gas bill: if the house burned about 1,500 m³ a winter, it needs about 6.5 kW at −15 °C. Four units that heat down to −30 °C give about 11.7 kW on paper, with a margin. Over a season the electricity costs about 14,900 lei instead of 39,200 lei of gas.

An air conditioner is a heat pump
An air conditioner that heats is an air-to-air heat pump: it takes heat from outdoors and gives it to the air in the room, about 3 kWh of heat per 1 kWh of electricity on average. An air-to-water heat pump heats water for radiators and underfloor heating; that is a different system and we do not install it. The difference is explained in Heat pump or air conditioner for heating a home.
How much heat a 100 m² house needs
Floor area alone says little: an insulated house and an old uninsulated one of the same size can differ several times over in heat demand. The best clue is how much gas the house burned in a winter. The figure is on your bills and shows how much heat the house really loses.
| Gas per winter | Heat needed at −15 °C | Rated heating output of the units, with margin | Gas per season | Air conditioners per season |
|---|---|---|---|---|
| 1,000 m³ | 4.3 kW | 5.6 kW | 26,100 lei | 9,900 lei |
| 1,500 m³ | 6.5 kW | 8.4 kW | 39,200 lei | 14,900 lei |
| 2,000 m³ | 8.6 kW | 11.2 kW | 52,300 lei | 19,900 lei |
| 2,500 m³ | 10.8 kW | 14.0 kW | 65,400 lei | 24,800 lei |
“Heat needed” is what the house loses in hard frost. The heating output on an air conditioner’s spec sheet is measured at +7 °C outdoors, and in frost it gives less. So we take the total rated output of all units with a margin of about a third: that is the third column.
If the house had no gas, or burned it together with wood, this method does not work. Then the technician calculates at the free survey: room sizes and heights, windows, walls, insulation.
How many units and which
An air conditioner heats the room it is in. So a house gets not one big unit but one in each living room or bedroom. One powerful unit in the hallway will not heat the house: the heat does not reach the far rooms, and near the unit it is cold and noisy. Why is explained in One air conditioner in the hallway for the whole flat.
Example for a 100 m² house: a living room with kitchen and three bedrooms. We take models that heat in frost down to −30 °C:
| Room | Air conditioner | Rated heating | Installed |
|---|---|---|---|
| Living room with kitchen, 30–35 m² | TCL SaveIN AI 12 | 3.57 kW | 13 240 lei |
| Bedroom 1, 12–15 m² | TCL SaveIN AI 09 | 2.7 kW | 12 060 lei |
| Bedroom 2, 12–15 m² | TCL SaveIN AI 09 | 2.7 kW | 12 060 lei |
| Bedroom 3, 12–15 m² | TCL SaveIN AI 09 | 2.7 kW | 12 060 lei |
Together, about 11.7 kW of rated heating. Including the frost margin, that is enough for a house that burned up to 2,000 m³ of gas a winter. The installed price includes the unit and installation in one visit; pipework and brackets are charged by the metre, and the technician gives the total at the survey. Other models are in Air conditioners with heating: if the house stands in an exposed spot, take a model with extra frost margin, such as the ZEUS M-Pro, down to −35 °C.
- The hallway warms through the open doors of the bedrooms and living room.
- The bathroom is not heated with an air conditioner: keep the towel rail or underfloor heating there.
- Two floors need a unit on each floor: warm air rises, and one unit downstairs will not heat the upper floor evenly.
Multi-split or separate units
A multi-split is one outdoor unit for several rooms. The façade looks tidier, but for main heating it has two drawbacks:
- Frost. The multi-split outdoor units in our catalogue heat down to −20 °C (Cooper&Hunter) and −15 °C (Daikin). Separate cold-climate units go down to −30 °C and lower.
- One unit for the whole house. If the outdoor unit breaks, every room goes cold at once. With separate units the others keep heating.
A multi-split works well when the façade has room for only one outdoor unit, or when the air conditioners only help a boiler in autumn and spring. Models and prices are in Multi-split systems, and a two-room comparison in Multi-split for two rooms.
What a season costs
Take a house that burned 1,500 m³ of gas a winter. Gas for the same winter costs about 39,200 lei. The air conditioners give the same heat for about 14,900 lei of electricity a season. January is the most expensive month, about 3,400 lei, and more in hard frost; in October, November and March the bill is much lower, because at +5…+10 °C an air conditioner is at its most efficient. A month-by-month calculation is in How much does heating with an air conditioner cost per month.
If the house has a boiler, you do not have to remove it. The air conditioners take over most of the winter, and the boiler stays for the hardest frosts and for hot water, which air conditioners do not heat.
Wiring
In frost, four inverter units in a house like this draw about 3.2 kW from the grid together, more while warming up a cold house. Check what power your contract with the grid allocates to the house. The technician will look at the wiring and breakers at the survey and tell you whether anything needs changing.
How it is installed
First, a free survey: the technician looks at the house, checks our per-room output calculation and picks spots for the outdoor units, above snow level and not under the roof runoff. Then installation: one unit in one visit costs 1 600 lei, with pipework and brackets by the price list. You can pay in instalments.
Approximate calculation. Tariffs: gas 26.14 lei/m³ (ANRE, from 01.10.2026), electricity 3.56 lei/kWh (Premier Energy, ANRE, from 02.04.2026). 1 m³ of gas ≈ 9.3 kWh, boiler efficiency 90 %. Seasonal COP of the air conditioner 3, at −15 °C 2. Heat demand in frost is estimated from winter gas use and average monthly temperatures in Chișinău (heating season from mid-October to mid-April). The 30 % margin is an assumption: how much output drops in frost depends on the model. Prices as of 20 November 2026, from the catalogue.