In short. Refrigerant in an air conditioner is not used up like petrol in a car: it circulates in a closed circuit. If there is less of it, there is a leak somewhere. Five signs: weaker cooling, frost on the outdoor unit’s valves, oily stains on joints, hissing, non-stop running or an error. Do not top it up “by eye” — find and fix the leak first. The technician’s work is 350 lei, R32 refrigerant 200 lei per 100 g.

Where leaks come from
In a working unit refrigerant lasts for years. It almost always escapes through one of these places:
- pipe joints at the indoor and outdoor unit — the most common spot, especially if the pipes were badly flared during installation;
- the outdoor unit’s service valves and their caps;
- heat exchangers — from corrosion and vibration, more often in old units;
- the pipe run, damaged or crushed during balcony renovation, facade insulation or window replacement;
- removal without pump-down: if the unit was taken down and moved without pumping the refrigerant into the outdoor unit, all of it is gone.
“Badly flared pipes lead to a leak: the unit stops cooling, the compressor overheats, the unit burns out — and there is nothing you can do, you have to buy a new one.”
— Egor Martynov, director of Arctica Service (translated from Russian). Video, 19:09 · podcast chapter on the site
5 signs your unit is losing refrigerant
- It cools (or heats) less than before, even with clean filters. The room does not reach the set temperature; the air from the unit is “cool” rather than cold.
- Frost or ice on the thin pipe and the outdoor unit’s valves in cooling mode. In winter, in heating mode, frost on the outdoor unit’s coil is normal: the unit defrosts from time to time (see Why your air conditioner does not blow warm air straight away in winter).
- Oily stains on pipe joints, on the outdoor unit’s valves or on the wall below them. Compressor oil escapes together with the refrigerant, dust sticks to it, and you get a dark greasy stain.
- Hissing or whistling at the joints that was not there before. A brief gurgle and clicks at start-up and during defrost are normal sounds.
- The unit runs without pauses and the electricity bill grows, or it stops by itself and shows an error. Many models protect the compressor and display an error code; check what it means in your model’s manual — codes differ between brands.
No single sign proves a leak. Only a pressure reading with gauges tells for sure — a technician does it in 40–60 minutes.
Looks like a leak, but is not
| What you see | Most likely | What to do |
|---|---|---|
| Weak cooling, the unit has not been cleaned for over a year | Clogged filters and coils, not a leak | Rinse the filters; if that does not help — cleaning |
| In winter the outdoor unit frosts up, then steams and drips | Defrost in heating mode — this is normal | Nothing, heating returns in 5–10 minutes |
| Water drips from the indoor unit | Usually a blocked drain; less often — ice melting because of low refrigerant | Cleaning with drain flush, or diagnostics |
| Will not start, an error flashes | Many possible causes, cannot be told by eye | Write down the code and model, book diagnostics |
If the unit has not been cleaned for over a year, start with cleaning for 1 000 lei: it is cheaper and often solves the problem. Other common “faults” you can check in five minutes are in Air conditioner not heating, leaking or showing an error.
Is it dangerous?
For people, in an ordinary flat the risk is small. Household refrigerants (R32, R410A) have low toxicity. But they are heavier than air and in high concentration displace oxygen, and R32 is classed as mildly flammable. If it hisses loudly at the indoor unit: switch the unit off, open the windows, keep open flames away and do not touch the leak — liquid refrigerant causes frostbite.
For the air conditioner, yes. Refrigerant does not only cool; it also carries heat away from the compressor, and oil circulates with it. When refrigerant is low, the compressor overheats and wears out. A new compressor costs thousands of lei, and on an old unit the repair can cost more than a new one.
What to do, step by step
- Rinse the filters in warm water and dry them — 10 minutes. If the cold air is back, it was dirt.
- Look at the outdoor unit if you can reach it from the balcony: frost on the valves, oil on the joints? Do not unscrew the valve caps or tighten the nuts.
- Switch the unit off if the signs remain, so as not to strain the compressor.
- Book a refrigerant refill with leak search. The technician measures pressure, looks for the leak at joints, valves and heat exchangers, and names the cause and price before starting. A leak at a joint is fixed on the same visit. If all the refrigerant is gone or the circuit was opened, the circuit is vacuumed. Then it is charged by weight, per the outdoor unit’s rating plate, and checked in operation.
- If it is unclear what is wrong (error on the display, will not start, noisy), book diagnostics: pressure, electrics, drainage, a written report and quote.
What it costs
| What | Price |
|---|---|
| Diagnostics, if the cause is unclear | 350 lei |
| Technician’s work on a refill: pressure check, leak search, charging by weight | 350 lei |
| R32 refrigerant, per 100 g added | 200 lei |
| Leak repair, if one is found | quoted before any work |
How much refrigerant is added depends on how much escaped: you pay only for what is added. The full charge is printed on the outdoor unit’s rating plate. If we do the repair, diagnostics is included in its price.
An old unit on R22
If your unit is many years old, check the outdoor unit’s rating plate: it states the refrigerant type. R22 is the refrigerant of old units; it is being phased out under the Montreal Protocol, so it costs more than R32 and is harder to find. A unit is charged only with the refrigerant on its plate — different types must not be mixed.
If an old unit has a leaking heat exchanger or a damaged compressor, work out honestly what makes more sense. On the repair page we show both sums side by side: the quoted repair and a new unit with installation. New models are in Inverter air conditioners; catalogue prices include installation.
If you heat with your air conditioner in winter
A unit short of refrigerant heats as poorly as it cools — and you will notice at the first frost. If weak heating appeared together with frost on the valves or oil on the joints, have the pressure checked now, not in January. If we did the installation and the installation warranty is still valid (2 years, up to 5 with annual cleaning by us), call us first: if the leak is due to the installation, it is our responsibility under the warranty.